cover image: TECHNICAL REPORT - STATE OF THE ART: CCS TECHNOLOGIES 2024

TECHNICAL REPORT - STATE OF THE ART: CCS TECHNOLOGIES 2024

14 Aug 2024

The PSA off-gas is power plant is first treated in a pre-treatment unit, which compressed, dried and sent to a cryogenic unit, where aims to cool the gas and remove the SOx, HF, HCl, part of the CO₂ is separated from the other components by a the NOx, and dust. [...] solvent stability (no degradation observed), low energy The DMX™ solvent consists of a mixture of two organic compounds in aqueous solution, which is demixing under certain The CO₂-rich solvent is preheated in the lean/rich solvent consumption and purity of the captured CO2 for a wide conditions of temperature and CO2 partial pressure in the regeneration section. [...] Pre-treatment of the flue gas is vital for the operation and economics of the process to result in the optimum effectiveness of the carbon capture technology. [...] The rotating desorber can be is distributed from the inner axis and horizontally flung described as a lightweight pressurised shell-and-tube heat outwards in the direction of the wall of the column, while exchanger where the “hot-side” tube bundle rotates to the flue gas moves vertically from the bottom to the top. [...] The design basis accounted Before entering the core of the capture cycle, the flue for the challenging conditions of the US Gulf Coast and gas heat is recovered, utilising a pressurised clean the Middle East, handling hot ambient temperatures with gas absorber stream to generate an overall surplus of minimised plant cooling and neutral water balance.
Pages
113
Published in
Australia

Table of Contents