The distances between the particles, the sizes, and the temperatures of the particles were used as metrics for comparing the particles within the frames. [...] Fire 2020, 3, 68 4 of 17 The MOTP metric is used to evaluate the posit∑ioning accuracy of tracked particles and can becalculated by the formula ∑ dti,tMOTP = i (7) t ct where dti is the distance between the ground truth, that is, annotated particles and the particles predicted by the code with the number I in the frame; ct is the number of matches found in the frame with the number t. [...] The MOTA metric is based on the frequency of false positives, the frequency of missed detections, and the frequency of errors in assigning a detec∑tion number: t(mt +∑f pMOTA 1 t + mmet)= − (8) t gt where mt is the number of missed detections, f pt is the number of false positives, mmet is the number of mismatches; gt is the number of objects in the frame t. [...] The set of images was then analyzed using a detector and the errors in the geometric dimensions of the object were calculated, dependent on the distance from the focal length. [...] The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.